TROUBLE SHOOTING AND SOLUTIONS
Errors
The appliance does not
work�
Warning lamp for to less
water lights up�
The condenser does not
work�
The condenser works, but
no ice cubes
are produced�
The ice cubes do not fall
at all or only partially into
the container�
The ice cubes always stick
together�
32
Possible causes
Problems with the main
electricity connection.
Ambient temperature is under
10°C.
Water intake disturbed
Valve is damaged.
Water pressure is too low.
Not enough water.
Ice collector container is full.
Leak in the cooling system.
Condenser dusty.
Ambient temperature or water
temperature are to low.
Valve is damaged.
Storage tank is not sufficiently
cooled.
Stand 12/2012 WBS / 10/2018 TM
Solutions
Switch off and after 5 minutes restart.
Restart, if the ambient temperature is
higher.
Check the water intake
Check valve, if necessary, let it
exchange.
The water pressure has to be at least 1
kg/cm2.
Check the water supply.
Empty the container.
Kühlsystem vom Fachmann überprüfen
lassen.
Kondensator staubfrei machen,
Lüftungsschlitze reinigen
Ambient temperature has to be at least
10°C and water temperature at least
7°C.
Exchange the valve.
Often emptying.
Do not leave overnight in the storage
tank.
Control temperature.