3.
Installation
3.1.
Mounting the control unit
• Disconnect from the mains <41> and open the housing,
to do this loosen the two screws <34> (turn anticlockwise)
and open the housing cover.
• Mount the housing in the designated spot, using both
attachment possibilities to do this. There is a
drilling template included in the scope of delivery.
• Close the housing cover and tighten both screws
<34> (turn clockwise).
3.2.
Connecting the wastewater pump(s)
Connect the wastewater pump(s), to do this connect
the cable plug for the pump <40> as shown in Fig. [7].
Tighten the nut using 3 Nm. The gap <35> between
nut and plug-type connection must then be 3-4 mm
(See Fig. [8])
The pump cable can be lengthened or shortened.
Refer to section 5.1 Shortening or lengthening the
pump/probe connection cable
INSTALLATION
[7]
[8]
28/120