Herunterladen Inhalt Inhalt Diese Seite drucken

Beko ATH8130 Bedienungsanleitung Seite 9

Verdunstungsbefeuchter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 58
3
Function information
Smart humidification mode
: When the humidity level is below 45%, the machine will enter into
standard humidification mode plus heat humidification. When the humidity level is between 45% and
60%, the machine will enter into standard humidification mode. When the humidity level is over 60%,
the machine will enter into sleep humidification mode where the indicator light shows normally. When
the humidity level is over 70%, the machine will enter into standby mode.
C
Note: Humidity control and heat humidification keys are not available in smart mode.
We recommend that you select sleep humidification mode when sleeping. The machine has very low
noise in this mode, thus it will not affect your sleep quality.
3. Heat humidificaiton
There are 2 working states of heat humidification: sleep humidification mode + heat humidification,
standard humidification mode + heat humidification.
Sleep humidification mode
+ heat humidification
: The motor operates at 700rpm, heating
power is 150W. The display screen only shows
+ indicator light of heat humidification
. When
the humidity is 5% over the set point, heating will stop, and also the motor will enter standby mode
after 1 minute; when the humidity is 5% below the set point, it will reenter heat humidification mode.
Standard humidification mode
+ heat humidification
: The motor operates at 1000rpm,
heating power is 200W. When the humidity is 5% over the set point, heating will stop, and also the
motor will enter standby mode after 1 minute; when the humidity is 5% below the set point, it will
reenter heat humidification mode.
We recommend that you select sleep humidification mode when sleeping. The machine has very low
noise in this mode, thus it will not affect your sleep quality.
4. Humidity control
Press the humidity control key, the machine can be set to -- and 11 humidity levels including 40%,
45%, 50%, 55%, 60%, 65%, 70%, 75%, 80%, 85%, 90%. When the machine detects the ambient
humidity is 5% higher than the set point, it will automatically stop working. The display screen shows
"set humidity" and "current humidity" at the same time. When the ambient humidity is 5% lower than
the set point, the machine will automatically start working.
5. Timer
Press "Timer" to set time. It has 13 reserved times to select from "0-12 hours". Select the needed time.
After the set time flickers for 5 seconds, the current humidity will show on the screen. The sum of
numbers on the top right of the screen is the remaining time.
9 / 28 EN
Evaporation humidifier / User Manual

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis