Herunterladen Inhalt Inhalt Diese Seite drucken

Ecler MPAGE16 Bedienungsanleitung Seite 6

Tisch-paging-konsole
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Power can be supplied directly from MIMO88 through pins 1 and 2 of the remote devices
bus connector. In some cases, it will be necessary to use WPPSU optional 15V AC-DC adapter to
meet consumption requirements of the setup, depending on the number of MPAGE16 and / or
WPtouch devices installed and on the wiring type and length. If this external power supply is used, it
must be connected between + DC and GND for the console and the DC + terminal must not be
connected to MIMO88. If in doubt, contact our technical support.
2.
Touch keys sensitivity adjustment (optional).
TOUCH SENSITIVITY jumper position inside the unit:
x
HIGH: default position, with TOUCH SENSITIVITY jumper in place
x
LOW: TOUCH SENSITIVITY jumper removed
TOUCH
SENSITIVITY
LOW
HIGH (DEFAULT)
JUMPER
3.
Programming and implementation of the MIMO88-MPAGE16 set from EclerNet
Manager application
6
c.
The microphone balanced audio signal (MIC +, MIC-, GND) should be
connected to one of the 8 MIMO88 audio inputs (IN 1 to IN 8)
MPAGE16 touch keys sensitivity has two possible settings, depending on the
-
(6)
MIC
(5)
MIC +
(4)
CAN L
(6)
(1)
+ DC
(1)
GND
(2)
CAN H
(3)
NETWORK LED

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis