Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Nibe VPA 300/200-CU Montage- Und Bedienungsanweisung

Vorschau ausblenden Andere Handbücher für VPA 300/200-CU:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
Hot water capacity
Charge power
(kw)
4
7
10
15
NL number: According to DIN 4753
T50: Heating time from 10 to 50 °C.
Vmax: Maximum hot water volume at 55 °C in the water
heater. 12 l/min gives 420 litres 40 °C mixed water.
Technical specifications
PED 97/23/EC
Type
Volume, water heater
Volume, double-jacketed
Net weight
Sacrificial anode length
Max. immersion heater length
Max preassure, water heater
Max preassure, double-jacketed
Anti-corrosion
Part No
6
NL
T50
(minutes)
number
2,5
250
2,75
160
3,0
110
3,25
75
Accessories
Direct-current anode
Part no 034 208
Enclosed kit
Insulation plug
All cover discs
Installation and Maintenance Instructions
VPA 300/200-CU
litres
300
litres
190
kg
180
mm
-
mm
650
bar
9
bar
3
Copper
088 710
VPA 300/200
VPA 300/200-E
300
190
170
min 790 mm
650
9
3
Enamel
088 700

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vpa 300/200-e

Inhaltsverzeichnis