Herunterladen Inhalt Inhalt Diese Seite drucken

Installation - Nibe VPA 300/200-CU Montage- Und Bedienungsanweisung

Vorschau ausblenden Andere Handbücher für VPA 300/200-CU:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6
2
4
8
7
10
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Rights to make any design or technical modifications are reserved.
4
INSTALLATION AND MAINTENANCE INSTRUCTIONS
VPA 300/200
9
3
1
5
Ø 750
100
85 85
95
Equipment
1
Cold water inlet
2
Hot water outlet
3
Hot water circulation
4
Docking connection, incoming from the external heat
source, G1
5
Docking connection, outgoing to the external heat
source, G1
6
Air nipple, double-jacketed space
7
Immersion heater connection G2"
8
Pocket tube (female ø11 mm), control hot water
heating
9
Lifting eye
10
Adjustable feet
40
Sacrificial anode (VPA 300/200-E)
95
Serial number label

Installation

The water heater is unscrewed from the pallet and lifted
into position, use the lifting eye on the top if necessary.
The water heater can be made less bulky by removing the
insulation, see the cover's inside ; (the diameter of the
water heater without insulation is Ø 650)
Loosen all the screws along the joining plate on both
jacket halves.
Lift off the top cover
Pull the insulated jacket halves straight off.
Assembly takes place in the reverse order. If the screws are
difficult to fit in the old holes the plate can be turned upside
down, which gives new, unused holes in the insulated
jacket halves.
The water heater may only be installed vertically and can be
aligned using the adjustable feet (10).
Once the water heater is in the correct position, remove the
lifting device from the top.
NOTE! Fit the cover discs before the pipe installa-
tion is made.
VPA 300/200
Copper: Ø28 mm Cu-pipe
Enamel: G1" male
Copper: Ø28 mm Cu-pipe
Enamel: G1" male
Copper: Ø15 mm Cu-pipe
Enamel: G3/4" male
1
/
"
2
1
/
"
2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vpa 300/200-e

Inhaltsverzeichnis