Storing the Measured Values
The unit makes possible the storing of the measured values by two meth-
ods:
Adding/subtracting measured values: The results of individual
measurements can be added or subtracted and the sum or difference
displayed.
List of the last 20 measured results: In addition, the unit stores au-
tomatically the results of the last 20 measurements and can display
them.
Both methods of storing are called up with the memory recall button
14.
Adding/Subtracting Measured Values
Storing/Adding Measured Values
For example, if an area value is stored in the memory and the current
measurement is a volume value, the addition cannot be performed. In the
display, the "ERROR" message blinks briefly.
Subtracting Measured Values
By pressing the
deducted from the value stored. In the display, "M–" appears briefly and
then "M".
If a value is already stored in memory, the new value is subtracted from
the contents of memory, however, only when the measuring units agree
(see Storing/Adding Measured Values).
Displaying Stored Values
Clearing the Memory
To clear the memory contents, first press the
recall until "M=" appears in the display. Then press the clear
ton 12; the "M" no longer appears in the display.
1 609 929 E99 • (03.09) T
By pressing the
the bottom of the display – either a length,
area or volume value depending on the cur-
rent measuring function – is stored in memory.
In the display, "M+" appears briefly and then
"M".
If a value is already present in the memory, the
new value is added to the memory contents,
however, only when the units of the measure-
ments are in agreement.
button 15, the value at the bottom of the display is
By pressing the button for memory recall
14, the value stored in the memory is
displayed. In the display, the memory symbol
"M=" appears.
When the memory content "M=" is shown in
the display, it can be doubled by pressing the
button 16 or set to zero by pressing the
button 15.
English–9
button 16, the value at
button 14 for memory
but-