Herunterladen Inhalt Inhalt Diese Seite drucken

Kärcher WPD 100 Basic Originalbetriebsanleitung Seite 21

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installing/removing filter
WARNING
Health risk due to the contamination with germs.
When replacing the filter cartridges, ensure hygiene and
cleanliness.
Do not touch the connections of the socket and filters.
Wear sterile disposable gloves when replacing the filter.
 Shut off water supply to the appliance.
 Place the container under the water output of the
appliance.
 Press the button for unchilled water until no more
water is dispensed.
 Set the appliance switch to "0".
 Remove drip pan and open the device door.
1
Bracket
2
Plate
3
Filter
4
Handle
a
Remove the filter.
b
Insert filter
 Turn the filter to the left until the tab is visible.
 Pull the filter downwards out of the support and re-
move it.
Note:
The used filter can be disposed of as domestic waste af-
ter the water has been drained.
 Wear sterile gloves.
 Unpack the new filter.
 Turn the filter so that the handle is on the left side
and insert it into the relevant support from the bot-
tom.
 Turn the filter to the right all the way to the stop.
1
Bracket
2
Filter
 Check installation position.
The marking on the label on the support and on the
filter must be aligned with each other.
Note
If both filters are replaced at the same time, also replace
the other filter at this time. The subsequent rinse pro-
cess can be performed on both filters simultaneously.
Note:
Filters must be installed in the same position and
must not be interchanged! Observe marking!
 Close device door and insert drip pan.
 Place an receptacle underneath the water outlet.
 Set the appliance switch to "I".
 Open the water supply again.
 Place an receptacle underneath the water outlet.
 Operate the button for unchilled water.
The new filter is flushed.
 The maximum dispensing time is limited to 60 sec-
onds. To resume the rinsing process, press the
button for unchilled water again.
 Rinse the filter until the dispensed water is clear
and odour-free, however, at least with 20 litres.
 After every filter change the performance of a
chemical cleaning is recommended (see "chemical
cleaning").
Uninstalling and installing the UV-lamp
The lamp of the UV light must be replaced every six
months.
 Disconnect the mains plug from the socket.
 Set the appliance switch to "0".
 Remove drip pan and open the device door.
1
Cover cap
2
Top holder
3
UV-lamp
1
Safety button
 Tilt the UV-lamp forwards out of the holder at the
top.
The safety button behind the UV light is triggered.
7
-
EN
1
Top connector
2
Illuminant
3
Lock nut with seal
4
UV-lamp
Note
Do not unscrew the lock nut with seal (water leak).
Avoid rotary movements when pulling out the lamp.
 Remove the cover cap.
 Pull the lamp approx. 10 cm out of the cylinder.
 Remove upper plug.
 Pull the lamp out of the cylinder.
1
Illuminant
2
Bottom connector
3
UV-lamp
 Remove lower plug.
 Remove lamp and dispose of via household rub-
bish.
ATTENTION
Lamps are sensitive to grease. To not touch lamps with
bare fingers. Prior to installation, clean soiled lamps by
means of a dry, grease-free cloth.
 Remove new lamp from the packaging.
 Attach lower plug to the new lamp.
 Slide the lamp approximately halfway into the UV
light.
Note
Carefully slide the two cables of the lower plug simulta-
neously with the lamp into the UV-lamp.
 Attach upper plug to the lamp.
 Slide the lamp all the way into the UV light.
 Fit cover.
 Fold back the UV-lamp and snap into the upper
support.
The safety switch is operated.
 Close device door and insert drip pan.
 Insert the mains plug into the socket.
 Set the appliance switch to "I".
21

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wpd 200 basicWpd 600 basic

Inhaltsverzeichnis