1. Safety Guidelines
1.
Follow the installation instructions.
2.
Use the appliance
according to its intended use
in good condition
with due regard to safety and risk of danger.
3.
Note that the appliance is exclusively for use in the ap-
plications detailed in these installation instructions. Any
other use will not be considered to comply with require-
ments and would invalidate the warranty.
4.
Please take note that any assembly, commissioning,
servicing and adjustment work may only be carried out
by authorized persons.
5.
Immediately rectify any malfunctions which may influ-
ence safety.
2. Functional description
Hard or medium-hard drinking water contains large amounts
of lime, which can deposit in pipes, fittings and devices and
result in irreparable damages.
KaltecSoft is based on the simple exchange of minerals. Cal-
cium and magnesium is replaced by sodium, thus preventing
additional scale build up.
3. Application
Medium
Water
Water temperature
5-30°C
Operating pressure
2,0-8,0 bar
4. Technical data
Ambient temperature
Nominal pressure
Nominal flow rate (∆p=1,0 bar)
Nominal flow rate (∆p=1,8 bar)
Reverse rinsing max. (∆p=1,8 bar) 1,6 m
Supply voltage (ext. transformer)
Protective extra low voltage
Power consumption
Protection class
Connection size
Connection sewerage
5. Options
Type
Resin volume (l) Waste water,
PW50-AS KaltecSoft
PW50-BS KaltecSoft
PW50-CS KaltecSoft
www.honeywell.com
2-40°C
PN 10
3
1,4 m
/h
3
1,8 m
/h
3
/h
230 V / 50 Hz
24 V
2 W (during treatment)
IP 22
3/4" external
1/2" hose nozzle
regeneration water
(l/regeneration)
10 litres
50
15 litres
78
20 litres
102
GB
6. Scope of delivery
The water softener consists of:
Cabinet in modern, space-saving design
Electronic regeneration system controlled by volume
Control panel with status indicator
Bottle with monodisperse ion exchanger
Connector adapter, incl. Bypass valve
External transformer; the device is only fed with a protec-
tive low voltage of 24 V
Filter combination FK06
7. Assembly
7.1 Installations Guidelines
All works should only be carried out by a qualified person
Ensure that installation is not subject to freezing or
extreme heat
A drain connection within five meters distance or two
meters height must be available. The drain hose must
not be kinked in any way as this will lead to an overflow
of the device
After the device has been installed, the time and the
water hardness should be set on the appliance and a
manual regeneration be initiated
If the supply pressure exceeds 8.0 bar, a pressure re-
ducer has to be connected!
If the supply pressure exceeds 4 bar, it is recommend-
ed to fit a pressure reducer upstream the device.
7.2 Assembly instructions
In order to avoid irreversible damages to the water
conditioning device, all welding and soldering work in
the immediate vicinity has to be completed prior to as-
sembly!
1.
Thoroughly flush pipework
2.
Install the water conditioning device
Note flow direction (indicated by arrow)
Install without tension or bending stresses
3.
Connect the water conditioning device
4.
Connect the sewerage tube to the discharge connection
(inner tube ø min. 13 mm, 1/2")
Make sure the seal is fitted properly!
9
MU1H-1412GE23 R0608