INITIAL USE / MAINTENANCE

First attach a type of tow rope (nylon cord or similar) to the pump so that
you can pull it out of the water if necessary.
Connect the corresponding hoses of your aquarium/pond/spring fountain
etc. to the pump. Make sure that there are no air bubbles in the pipe
system.
Install the pump at least 20 cm and at most 2.8 m (Lagoon 3600) or 4.8 m
(Lagoon 5200) below the water surface.
Do not place the pump in the dirt or sediment at the bottom of the water,
but in a slightly elevated position.
Protect the power cable from damage from kinks and/or sharp edges when
laying it.
Connect the pump to the power outlet.
Note: Never operate the pump without the filter basket (1). The filter
protects the pump from dirt and blockages caused by sediment, dust and
dirt. Do not operate the pump in dry conditions.
1. Adjust the flow rate in the direction as indicated by the arrow.
2. Turn the filter case in the direction as indicated by the arrow, then take it
out.
3. Move the blue switch to OPEN, then you can open the motor body, on the
contrary the motor body is locked.
4. Turn the motor body in the direction as indicated by the arrow, then take it
out.
5. Clean and change the impeller after taking out.
6. Make sure to put the O-ring at the right place (as shown in the pic).