2.
Description
PT6 Kit is designed basically to quickly identify or trace telephone, electrical
or alarm wiring. The probe is able to detect the powerful signal generated by
the toner - even at a considerable distance – at the cable termination for ex-
ample in telephone distribution cabinets or in pits. By generating an acoustic
signal (quiet in low and loud the signal is strong) and simultaneous illumina-
tion of the green LED (Fig. 1/c) PT6 probe identifies the correct wire. The
TG6 tone generator can only be used on non-busy lines.
3.
Operation
Connection to AC (230V
age the instrument and could result in severe injury and
death of the user.
Use caution around voltages above 30 V
V
Product warranty is voided immediately.
3.1. On/Off
PT6 Probe
To activate PT6 Advanced Tone Probe, push and hold the black on/off
button (Fig. 1/a): the bright white LED headlight (Fig. 1/e) for probing in
dim locations is always on. Releasing the black button (Fig. 1/a)will turn
the unit off.
TG6 Tone Generator
To turn on TG6 Tone Generator, move the switch (Fig. 2/b) from OFF
in one of the two positions: SHORT or LINE.
To turn it off, move the switch to OFF.
3.2. Check short circuit
TG6 can check the test connection for a short circuit. Proceed as fol-
lows:
•
Connect the test leads to the inactive wires.
•
Switch the tone generator to the SHORT (Fig. 2/b) Position.
•
If a short is detected the LINE LED shows steady green and a
warning tone can be heard.
. These voltages pose a shock hazard.
∿
) power line voltages will dam-
-
20 -
∿
rms, or 60