Set the system to multi-user mode with the command code 8901. The system will stay in that mode until it is
refreshed.
MASTER
CODE
Refreshing the system
When choosing a different operation mode (see above), the system will reset and clear all values except for the
master code.
NOTE: Make sure the user code and the master code are both 4 digits long when operating in single user mode.
8. Programming and Use of the Keypad – Operation Examples
A) Programming procedures
a. Your HAA9523S is programmed from the keypad. All programmed information is stored in the non-volatile
memory.
b. Set the keypad into programming mode first with the master code and press
NOTE: Use the DAP jumper to set the keypad into programming mode in case you forgot the master code.
See "4. The DAP Jumper".
c. Go to a location and program the options. See "6. Programming the Keypad – Summary Chart".
d. Program the options until all options are programmed. Repeat the programming of an option in case of a
wrong entry.
LOCATION 1
...
LOCATION n
e. Exit the programming mode with
B) Single user mode operation – Example
1. Requirements
a. Single user mode
b. Change the factory-set master code 0000 to a personal master code 3289
c. Set user code 1 to 8321
d. Set user code 2 to 6854
e. Set user code 3 to 9270
f. Set output 1 to momentary mode, 1 second
g. Set output 2 to start / stop mode
h. Set output 3 to start / stop mode
i. Set the keypad to lock itself during 15 minutes after 10 successive false codes
2. Programming – Setting the above requirements into the keypad
v2 15/11/2013
HAA9523S
OPTION
OPTION n
. All input information has been saved.
Program mode with factory-set master code
Multi-user mode enabled. Wait 2-3 seconds after
pressing
until you hear confirmation beeps.
9
to validate.