The anode of the auxiliary red LED is connected to the +5V internally. It turns on with the cathode (wire 7)
connected to (-) ground.
• KEYPAD ACTIVE OUTPUT OR ALARM OUTPUT (8)
An NPN transistor open collector output with max. rating of 100mA sink and 24VDC. It is selectable to give
Keypad Active Output or Alarm Output via the K or A jumper.
1. Keypad Active Output (KEY)
It switches to (-) ground for 10 seconds with each press of the key. This can be used to turn on lights, CCTV
cameras or buzzer.
2. Alarm Output (AL)
Switches to (-) ground when the Door Forced Open Alarm or Door Propped-Up Alarm occurs in order to trigger
the external alarm to give notification at a remote location.
• OUTPUT 2 (9-10-11)
Auxiliary relay output with 1A N.O. and N.C. dry contacts controlled by user code 2 and ideal for controlling
security systems and automatic operators. It is programmable for start/stop (toggle) operation or timing operation
from 1 to 999 seconds.
• OUTPUT 3 (12)
An NPN transistor open collector output ideal for auxiliary control functions such as security systems. This output
is programmed for start/stop (toggle) operation or timing operation from 1 to 999 seconds. It switches to (-) ground
when active and the max. rating is 100mA sink / 24VDC.
• OUTPUT 1 DISABLE (13)
A N.O. input terminal refers to (-) ground. Neither user code 1 nor egress button can activate output 1 when this
terminal is tied to (-) ground. It is prepared for cross-wired connection in an interlock application.
• INTERLOCK CONTROL OUTPUT (14)
An NPN transistor open collector output. It is off at normal condition and switches to (-) ground immediately for the
first 5 seconds after keying in a valid user code to operate output 1. Then, it will keep tying to (-) during the time
that the door position sensor is open. Use this output to control the other keypad in an interlock system to prevent
both doors from opening at the same time.
• DURESS OUTPUT (16)
An NPN open collector output. It switches to (-) ground when the duress code is entered. Use it to trigger an
alarm zone or to turn on a buzzer to notify a guard. Ic max.: 100mA sink; Vc max.: 24VDC.
3. The Pacifier Tones & LED Indicating Signals
The built-in buzzer and the green LED indicator in the centre give the following tones and signals for operation status:
STATUS
1. In programmable mode
2. Successful key entry
3. Successful code entry
4. Unsuccessful code entry
5. DAP jumper not replaced
6. In standby mode
7. Output relay activated
NOTE: * All pacifier tones can be enabled or disabled through programming options at location 83.
v2 15/11/2013
HAA9523S
TONES*
- - -
1 beep
2 beeps
5 beeps
Continuous beeps
- - -
1-second long beep**
4
LED SIGNALS
ON
1 flash
2 flashes
5 flashes
Continuous flashes
1 flash in 2-seconds interval
- - -
VELLEMAN