Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Polar DN492 Bedienungsanleitung

Tiefkühltische
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29
Control panel
message
"EE"
"rPF"
"EPF"
"i1P"
"i2P"
"i3P"
"rtC"
"rtF"
"HA"
"LA"
"FF"
"PFA"
"OCF"
"EA"
"CA"
"dA"

Technical Specifications

Model
Voltage
Power
DN492
230V~
770W
50Hz
DN493
230V~
800W
50Hz
DN494
230V~
1300W
50Hz
DN492-DN493-DN494 _ML_A5_v4_170410.indb 9
Meaning
Data or memory failure
Thermostat Probe failure
Evaporator Probe failure
Insert probe 1, 2, 3, failure
Clock data lost
Clock failure
Maximum temperature alarm
Minimum temperature alarm
Fast freezing interrupted by short
power failure
Fast freezing interrupted by long
power failure
Maximum cycle time has been
exceeded
External alarm
Serious external alarm
Door open alarm
Weight
Current
Capacity
3.5A
3 x GN1/1
4A
5 x GN1/1
6.5A
10 x GN1/1
Required action
Call POLAR agent or qualified technician
Call POLAR agent or qualified technician
Call POLAR agent or qualified technician
Ensure insert probe has not become
disconnected from the socket
Reset date and time (
time)
Reset date and time (
time)
Alarm will automatically stop as soon as
the thermostat values returns to normal
values
Alarm will automatically stop as soon as
the thermostat values returns to normal
values
Call POLAR agent or qualified technician
Freezing cycle will restart from the current
phase
Product will continue to operate. Press any
key to deactivate alarm
Call POLAR agent or qualified technician
Call POLAR agent or qualified technician
Ensure door is closed fully
Max.
Chill
Ambient
(kg)
Rate
Temp.
104
43°C
90 min
(12kg)
116
43°C
90 min
(18kg)
185
43°C
90 min
(40kg)
UK
Resetting date and
Resetting date and
Freeze
Refriger-
Rate
ant
240 min
R290 150g
(8kg)
240 min
R290 150g
(14kg)
240 min
R404A
(28kg)
9
2017/4/10 11:12

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dn493Dn494

Inhaltsverzeichnis