Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Technical Specifications; Electrical Wiring - Polar G590 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für G590:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
Telephone Helpline: 0845 146 2887 (United Kingdom)

Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer.
Fault
The appliance is not working
The appliance turns on, but the
temperature is too high/low
The appliance is leaking water
The appliance is unusually loud

Technical Specifications

Model
Voltage
G590
230V 50Hz
G591
230V 50Hz
G592
230V 50Hz
G593
230V 50Hz
G594
230V 50Hz
G595
230V 50Hz
U632
230V 50Hz
U633
230V 50Hz
U634
230V 50Hz
U635
230V 50Hz
CC663
230V 50Hz
CD616
230V 50Hz
GD879
230V 50Hz
GD880
230V 50Hz

Electrical Wiring

POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Too much ice on the evaporator
Condenser blocked with dust
Doors are not shut properly
Appliance is located near a heat source or air flow to
the condenser is being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being stored in the
appliance
Appliance is overloaded
The appliance is not properly levelled
The discharge outlet is blocked
Movement of water to the drain is obstructed
The water container is damaged
The drip tray is overflowing
The safety band has not been removed
Loose nut/screw
The appliance has not been installed in a level or
stable position
Temperature
Power
Current
Range
300W
1.8A
-2°C to 8°C
600W
4A
-10°C to -20°C
300W
1.8A
-2°C to 8°C
600W
2.8A
-10°C to -20°C
600W
4A
-2°C to 8°C
700W
3.3A
-10°C to -20°C
350W
1.95A
-2°C to 10°C
850W
4A
-10°C to -20°C
800W
4.8A
-2°C to 8°C
900W
4.8A
-10°C to -20°C
600W
4A
-2°C to 8°C
700W
3.3A
-10°C to -20°C
600W
4A
-2°C to 8°C
700W
3.3A
-10°C to -20°C
Check the unit is plugged in correctly and switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Defrost the appliance
Clean the condenser
Check doors are shut and seals are not damaged
Move the refrigerator to a more suitable location
Increase ventilation or move appliance to a cooler position
Remove any excessive hot foodstuffs or blockages to the fan
Reduce the amount of food stored in the appliance
Adjust the screw feet to level the appliance (if applicable)
Clear the discharge outlet
Clear the floor of the appliance (if applicable)
Call POLAR agent or qualified Technician
Empty the drip tray (if applicable)
Remove the safety band
Check and tighten all nuts and screws
Check installation position and change if necessary
Capacity
Refrigerant
(litres)
440
R134a 210g
440
R404a 390g
600
R134a 210g
600
R404a 410g
1200
R134a 320g
1200
R404a 450g
650
R134a 300g
650
R404a 360g
1300
R134a 500g
1300
R404a 730g
1200
R134a 320g
1200
R404a 450g
960
R134a 320g
960
R404a 380g
UK
Action
Dimensions
Weight
H x W x D (mm)
(kg)
1950 x 680 x 700
125
1950 x 680 x 700
125
1990 x 680 x 830
135
1990 x 680 x 830
135
1990 x 1340 x 815
180
1990 x 1340 x 815
180
2010 x 740 x 830
134
2010 x 740 x 830
138
2010 x 1480 x 830
198
2010 x 1480 x 830
208
1990 x 1340 x 815
180
1990 x 1340 x 815
180
1950 X 1340 X 700
165
1950 X 1340 X 700
165
5

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis