DC voltage
basic accuracy
input impedance
maximum input
AC voltage
basic accuracy
input impedance
frequency range
maximum input
DC current
basic accuracy
AC current
basic accuracy
resistance
basic accuracy
overload protection
capacitance
accuracy
frequency
basic accuracy
overload protection
temperature
basic accuracy
maximum display
LCD display size
power supply
dimensions
weight (with battery) ±303g
00 (28/11/2008)

Technical specifications

0.4/4/40/400/600V
±(1.5% of rdg + 2 digits) / ±(0.8% of rdg + 2 digits) for 0.4V range
/ ±(2.0% of rdg + 2 digits) for 600V range
10Mohm
600V
0.4/4/40/400/600V TRUE RMS
±(1.5% of rdg + 8 digits) / ±(1.0% of rdg + 10 digits) for 0.4V
range / ±(2.0% of rdg + 8 digits) for 600V range
10Mohm
50-60Hz
600V
40/400/1000V
±(2.8% of rdg + 10 digits) for 40A range / ±(2.8% of rdg + 8 digits)
for 400A range / ±(3.0% of rdg + 8 digits) for 1000A range
40/400/1000A TRUE RMS
±(2.8% of rdg + 10 digits) for 40A range / ±(2.8% of rdg + 8 digits)
for 400A range / ±(3.0% of rdg + 8 digits) for 1000A range
400/4K/40K/400K/4M/40M
±(1.0% of rdg + 4 digits) for 400ohm range / ±(1.5% of rdg + 2
digits) for 4K~400K range / ±(2.5% of rdg + 5 digits) for 4M range /
±(3.5% of rdg + 10 digits) for 40M range
15s max. 250V (all ranges)
4n/40n/400n/4µ/40µ/400µF/4mF/40mF
±(5.0% of rdg + 30 digits) for 4nF range / ±(5.0% of rdg + 20
digits) for 40nF range / ±(3.0% of rdg + 5 digits) for 400nF~40µF
range / ±(4.0% of rdg + 10 digits) for 400µF range / ±(5.0% of rdg
+ 10 digits) for 4mF~40mF range
4,000KHz
±(1.5% of rdg + 2 digits)
15s max. 250V (all ranges)
-40°C~1,000°C
±(2.5% of rdg + 3°C)
3999
22 x 35 mm
1 x 9V battery (incl.)
229 x 80 x 49mm
DCM268N