Herunterladen Inhalt Inhalt Diese Seite drucken

Battery Replacement; Technical Specifications - Velleman DCM269 Bedienungsanleitung

Mini-ac/dc-stromzange
Vorschau ausblenden Andere Handbücher für DCM269:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
6.

Battery Replacement

1. Replace the batteries when the low-battery symbol is displayed.
2. Turn off the device and loosen the screw of the battery compartment.
3. Remove the compartment cover and replace the two 1.5V AAA batteries.
4. Replace the cover and fasten the screw.
7.

Technical Specifications

DC current
AC current
basic accuracy
frequency
overrange
low-battery indication
maximum display
ranging mode
data hold
backlight
dimensions
weight
power supply
Use this device with original accessories only. Velleman nv cannot be held responsible in the event
of damage or injury resulting from (incorrect) use of this device.
For more info concerning this product and the latest version of this manual, please visit our website
www.velleman.eu.
The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this
manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the
prior written consent of the copyright holder.
V. 02 – 04/09/2013
DCM269
200 A
basic accuracy: ± 2.8 % + 8 digits
200 A
± 3.0 % + 8 digits
basic accuracy: 40-51 Hz: ± 1.2 % + 5 digits;
51-510 Hz: ± 1.2 % + 3 digits; 0.51-1 kHz: ± 1.2 % + 3 digits
yes
Yes
2400 counts
auto
yes
yes
160 x 50 x 30 mm
175 g
2 x AAA/LR03 battery (incl.)