Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - Monacor DMX-1TEST Bedienungsanleitung

Dmx-tester
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
CABLE CORRECT: o.k.
CABLE ERROR:
defective
CABLE REVERSAL: reverse polarity
The lower line shows the way the three poles
of the cable are connected.
Examples:
1–1
2–2
3–3:
each pole is correctly connected
1–1
2–*
3–3:
the connection of pin 2 is interrupted
1–1+2
2–*
3–3:
pin 1 and pin 2 are connected in an inadmis-
sible way
1–1
2–3
3–2:
cable connected with reverse polarity: pin 2
and pin 3 are crossed
Stop the cable test with the button MENU (3).
5.6 6. BACKLIGHT MODE
Via this item it is possible to adjust if the back-
ground illumination is to remain switched on
permanently or during the operation only.
1) Press the button ENTER (7).
2) Select with the button MODE (4):
ON: the illumination remains perma-
nently switched on
OFF: the illumination is switched off
approx. 20 s after the last button
is pressed and switched on again
when a button is pressed again
(recommended for operation with
rechargeable batteries)
3) With the button MENU (3) cancel the se-
lection or confirm with ENTER (the flash-
ing SETTING SAVE shows that the setting is
being saved).
5.7 7. POWER MANAGER
Via this menu item the operating time is
adjus t ed after which the unit is switched to
the energy saving mode. In this mode the
display is switched off and, if required, the
output of a DMX signal is stopped. The LEDs
DMX IN (2) and DMX OUT (6) shortly flash in
intervals.
The energy saving mode can only be
exited by pressing the button ENTER.
1) Press the button ENTER (7). The display
shows SLEEPING TIME and the currently se-
lected time after which the unit is switched
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
®
to the energy saving mode, measured from
switching on or from exiting the energy
sav ing mode the last time.
2) Select a new value (1 to 10 minutes) with
the buttons LEVEL RANGE (8). With the set-
ting "0 minutes" the unit is never switched
to the energy saving mode.
3) Cancel the selection with the button MENU
(3) or confirm with ENTER (the flashing
SETTING SAVE shows that the setting is be-
ing saved).
5.8 8. UNIT DISPLAY
This item allows to select in which format the
DMX values are displayed for the DMX out-
put (functions DMX OUT and AUTO FADE)
and as a presetting for the function DMX IN.
1) Press the button ENTER (7). The display
shows UNIT TYPE IS and the currently se-
lected display format.
2) Select one of the following possibilities
with the button MODE (4):
1. 000 – 255
decimal
2. 00H – FFH
hexadecimal
3.
0 – 100% per cent
3) Cancel the selection with the button MENU
(3) or confirm with ENTER (the flashing
SETTING SAVE shows that the setting is be-
ing saved).
After operation switch off the unit with the
switch POWER. If it is not used for a longer
period of time, disconnect the plug-in power
supply unit from the mains socket because
even with the DMX-1TEST switched off it has
a low current consumption.

6 Specifications

Power supply: . . . . . . . . . . .12 V ⎓ / 300 mA
via the supplied plug-in
power supply unit
connected to: . . . . . . . . .120 V – 240 V/ 50 – 60 Hz /
or 4 × 1.2 V rech. batt.: . type: NiMH, size: AA
DMX connections: . . . . . . .XLR, 3-pole
DMX address range: . . . . . .512 channels
Dimensions: . . . . . . . . . . . .141 × 58 × 105 mm
Weight:. . . . . . . . . . . . . . . .700 g
Subject to technical modification.
10 VA
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis