Technical Data:
Ambient temperature:
Storage temperature:
Minimum temperature stability
of the connecting lines:
Heating system, light and temperature sensors
at least 150 °C of temperature stability
Sauna control:
Dimensions (Wx H x D):
Type of protection:
(protection from splashing water)
Weight: approx.
1250 g
Nominal voltage:
400 VAC; 50/60 Hz; 3N
Switching capacity: AC1; 3 x 3.0 kW
Min. / max. pick-up capacity:
Connection to the main circuit as permanent wiring
(non-detachable connection).
Range of adjustment:
Temperature:
40 - 125 degrees Celsius
(refers to sensor location FI)
Light:
230 V, AC1:
1A
Switching capacity: max. 230 W
Operating instructions for the user
-10 °C to + 40 °C
-25 °C to + 70 °C
240 x 80 x 220 mm
IP X4
4,3 / 6,3 VA
Edition: 06-2010
Ident-No. O-A2-9
27