Errors and possible remedies

5.1

Automatic time limitation

The sauna control turns off after 6 / 12 hours of
continuous heating (depending on factory set-
ting).
For continued operation press the START /
STOP 8 key.
5.2

Interior lighting does not work

Turn off ON / OFF 1 key.
Turn off main fuse of the sauna control in the
fuse box.
Replace light bulb.
Contact customer service or the electrical engi-
neer, if the interior light still does not work. (look
at part 1, chapter 6)
5.3
ERROR Display messages
The sauna control is not ready-to-operate:
1. Turn off main fuse of the sauna control in the
fuse box.
2. Contact customer service or the electrical engi-
neer.
3. Mark the device as "defective".
26
Operating instructions for the user - Figure 5
5
Errors and possible remedies
With the following display error messages 4 you
can inform customer service of possible errors/de-
fects.
The error messages of the display mean:
E-F1:
Short-circuit or interrupted tempe
rature sensor line (white line)
E-24:
Excessive temperature fuse defect,
or (red) cable to excessive
temperature fuse interrupted.
E-P1:
Setting potentiometer for nominal
temperature defect.
E-51; E-52;
E-53:
Key 7 or 8 blocked
LL:
Temperature of interior
below 0°C
HH:
temperature of interior
above 140°C