SETTINGS
POWER BOX
To open the power box press against the latch from below and lift
the front cover up and forwards with care. Make sure that the cables
between the main board and the loudspeaker are not broken. The
loudspeaker is connected to the main board with a plug.
Ringer volume on the power box
You can use the potentiometer (3.4) to set the volume on the ringer
for the power box. Turn clockwise to increase and turn anti-clockwise to
reduce the volume.
Ringer and call volume on the outdoor station
You can use the potentiometer (3.8) to set the volume on the outdoor
station. Turn clockwise to increase and turn anti-clockwise to reduce the
volume.
Door opener switch
Use the slider switch (3.9) to set whether 12V activation of the door
opener is on or off. Normally the switch should be switched upwards
(away from the terminal).
Switching the ringer on the power box ON/OFF
Use the slider switch (3.11) to switch the ringer on the power box ON
or OFF.
Switching the ringer on the outdoor station ON/OFF
Use the slider switch (3.12) to switch the ringer on the outdoor station
ON or OFF.
NOTE: The ringer on the outdoor station and the power box is fixed and
cannot be changed.
MOBILE INDOOR STATION
Switch on
Use the slider switch (1.3) to switch the mobile Indoor station ON or OFF.
Set the ring tone
1. Press and hold the ' – ' volume button (1.10) for five seconds until
the indoor station sounds with the set ring tone. Then release the
button.
2. Press the ' – ' volume button (1.10) briefly to hear the
next ring tone.
3. Press briefly on the intercom button (1.4) to set the ring tone.
Set ringer volume
1. Press the ' – ' volume button (1.10) briefly to decrease the volume
and the ' + ' button to increase the volume.
2. Press the intercom button (1.4) to save the change in volume.
Set call volume
Use the volume button to set the call volume while carrying out a
conversation with the outdoor station. Pressing on the ' – ' button de-
creases the volume and pressing the ' + ' button increases the volume.
Switch temperature indicator °C/°F
1. Press and hold the ' + ' volume button (1.10) for five seconds until
the indoor station emits a tone. Then release the button.
2. Press the ' + ' volume button (1.10) briefly to switch
between °C and °F.
3. Press the intercom button (1.4) to save the – ° display
permanently.
CODING
If you have purchased a mobile indoor station with your system then
this needs to be coded to the system. AC-210 can be expanded to a
total of 4 mobile indoor stations, AC-220 to 2 mobile indoor stations for
each ringer button. Proceed as follows:
1. Press and hold the code button (3.5 or 3.6*) for five seconds until
the outdoor station emits a confirmation tone. Then release the
button.
2. Press and hold the intercom button (1.4) on the mobile indoor
station for five seconds until 'RE' appears on the display. Then
release the button.
3. Once coding is successful the outdoor station will first emit a
confirmation tone, followed immediately by the indoor station. The
display will also show the outdoor temperature after
coding is successful.
This process must be repeated for each indoor unit.
*Model AC-210 only has the code button 3.5, while model AC-220 has
both; code button 3.5 is for the upper ringer button while 3.6 is for the
lower ringer button. The relevant code button should be used depending
on whether you wish to configure an indoor station on the upper or
lower ringer button.
Resetting the coding on the power box
If the mobile Indoor station is exchanged because of a defect, it will be
necessary to completely delete the coding on the power box. To do this
please carry out the following steps on the power box: