WHAT
General
Inspection
Air Flow
Check
Cleaning of stage 1 filter
Replacement of stage
1 filter element
Replacement of stage
2 filter element
Replacement of stage
3 filter element
Replacement of seals
If the unit is used at higher temperatures (+50°C to +80°C), extra maintenance will be required (see table below) which
should be carried out in addition to the usual maintenance schedule. The gauge must be checked, and re-set if necessary,
after any exposure to the higher temperature range.
Infrequent exposure
8 hours exposure per day 12 months
Constant exposure

FAULT FINDING

Symptom
No air
Low air flow
Odour detected
If further servicing is necessary, contact your local 3M technical service.

STORAGE AND TRANSPORTATION

The equipment should be stored in the packaging provided in dry, clean conditions away from direct sunlight, sources
of high temperature, petrol and solvent vapours.
Do not store outside the temperature range -10°C to +50°C or with humidity above 80%.
The original packaging is suitable for transporting the product throughout the European Economic Community.
109526 Brochure P3E-CM Nieuw.ind8 8
109526 Brochure P3E-CM Nieuw.ind8 8
After 500 hours use unless otherwise indicated by
After 500 hours use or if odour is detected
Can be replaced at same time as elements if required
Replace seals (if not replaced regularly)
2.5 years
Possible Cause
External air supply turned off or
disconnected
Stage 2 filter clogged
Stage 3 filter saturated
WHEN
Before use
After use
Monthly if not in regular use
Before use
Monthly if not in regular use
After use
After 500 hours use
differential pressure indicator
Replace unit
5 years
2 years
12 months
Remedy
Turn on supply or check connection
Change filter element
Change filter element