Hints on built-in Wine Cellars
• Built-in wine cellars are front venting but are not designed to be fully integrated behind a joinery door.
• Please follow the installation diagram when installing built-in wine cellars.No less than the minimum instal-
lation dimension, or it will affect the venting of cellar.
• Built-in wine cellars draw air from right of ventilation frame (some models from the rear) and expel through
left of ventilation frame under the front door.
• Built-in wine cellars have a power switch located on the control panel so power point location is not critical.
• The power cord is 2.0m in length and is fixed on the right side at the back when looking from front of cabinet.
• As with most appliances of today, the wine cellar has sensitive electronic components which are susceptible to
damage through lightning and electricity supply faults. It is therefore advised to use a power surge protector to
avoid problems of this nature.
• Air vent on door must be provided for our built-in wine cellars when a wood door installed.
• In Hot climate zone, an air vent or grid, with a minimum ventilation size of 200 mm x 40 mm MUST be cut out
at the rear top of the back partitioning or at the top of either side of the partitioning, allowing cool fresh air full
access to flow into the 30mm gap located at the rear of the cabinet. This air vent or grid must not be opened
on the same side as other appliances such as ovens or an area that is sealed and without access to fresh cool
air. Failing to comply with the above specifications could result in WARRANTY void.
Installation Drawings for Models that use Lateral Condensation Cooling Mode