Herunterladen Inhalt Inhalt Diese Seite drucken

Removal Of Transport Packaging And Transport Safety Devices; Installation In The Container - TC KEMA 04ATEX1232 X Betriebsanleitung

Niveau - messwertgeber
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Removal of transport packaging and transport safety devices

Remove the KTX125... or KTX Level Transmitter carefully from the transport packaging.
See the instructions on the shipping packaging; remove all transport safety devices before
removing the KTX125... or KTX....Level Transmitter
Never forcibly remove the KTX125... or KTX Level Transmitter from the packaging by taking hold
of the guide tube!
Before installing the KTX125 Level Transmitter, the float safety bands must be removed. Make
sure all packaging components have been removed and that the float moves freely on the guide
tube.

Installation in the container

KTX125 Level Transmitters are installed in the container using flanges or mounting
plugs. (See the type designation on the product for the specific design of your Level
Transmitter )
Prior to installation, make sure the installation opening in the container agrees in size and
dimensions with the installation option of the KTX125 Level Transmitter.
Depending on the design of the KTX125 Level Transmitter,
the guide tube is inserted into the container from the outside.
Installation should be vertical. To ensure proper functioning,
the angle of installation must not exceed 30° from the vertical
position.
The guide tube of the KTX125 Level Transmitter is inserted
into the container from the outside through the installation
opening. The fastening work is carried out by tightening the
screw-in threads in the case of threaded plugs, screwing on
the union nut in the case of dairy fitting screw connections,
screwing together in the case of flange versions or closing the
clamping rings (articulated clamp) in the case of Tri-clamp
clamping connectors.
For KTX125 Level Transmitters featuring a
mounting plug, the thread must be screwed in for
the entire length of the thread.
KTX125
Level
Transmitters,
connection, are factory-equipped with a suitable union nut.
KTX125 Level Transmitters featuring flanges must be
installed using suitable bolts, washers and nuts.
KTX125
Level
Transmitters,
connectors, must be fastened using suitable tensioning rings
(articulated clamp).
3 /30
with
Dairy
fitting
with
Tri-clamp
clamping
Rev 8
screw
1
Terminal Box
2
Cable gland
3
Process Connection
4
Gasket
5
Guide tube
6
Float
7
Teflon washer
8
Set collar or Tension clamp
Abb. Level Sensor
1
2
3
4
5
6
7
8
max. 30°