Fault Analysis Sheet

The following table lists the most frequent causes of faults and the necessary
solutions
No function or
undefined
False 0 - 100%
values
KTX125 Level
Transmitters cannot
be attached at the
intended position on
the container
Please give us a call in case of any difficulties. We will do everything we can to
provide you with the required advice and help.
9 /30
Error
Possible Cause
Incorrect connection
Stop collars out of position
or replaced incorrectly
after the guide tube is
Reed contacts damaged
Float installed incorrectly
Incorrect ordering
Reed contacts damaged
Transmitter Calibration
Thread or flange
dimensions of Level
Transmitters incorrect
Thread of mounting plug
on container defective
Bolt threading on the
Level Transmitters
Insulation
removed
information
Transmitter or please
incorrect
Transmitter mounting
defective
Rev 8
Action
Compare with
connection diagram
Check terminals
Check position of
stop collar
Return to factory
Ensure 'Top' Mark is
uppermost
Please contact the
factory
Please contact the
factory
Calibrate the
contact the factory
Reworking mounting
on container
Reworking of Level
at factory
Reworking of thread
or replacement of
mounting plug
Send back to factory