Herunterladen Inhalt Inhalt Diese Seite drucken

Type Code Ktx - TC KEMA 04ATEX1232 X Betriebsanleitung

Niveau - messwertgeber
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Type Code KTX...

Basic type Code 1
KTX
A
Code 1:
A
= Version with terminal box Aluminium top
AU
= Version with terminal box Aluminium bottom
AV4
= Version with terminal box Stainless steel top
AV4U
= Version with terminal box Stainless steel bottom
AP
= Version with terminal box Polyester top
APU
= Version with terminal box Polyester bottom
APL
= Version with terminal box Polyester top (Ex – design)
APLU
= Version with terminal box Polyester bottom (Ex – design)
AVG
= Version with terminal box Stainless steel top with digital display
AVGU
= Version with terminal box Stainless steel bottom with digital display
Basic type
KTX
13 /30
Code 2
Code 3
Code 4
VK...
T...
L.../M.../..
.
Code 4: (Dimensions in mm)
L.../M.../12
L.../M.../14
L.../M.../16
L.../M.../25
Code 3:
TS
2-wire Standard
TE
2-wire Ex i
TLH
2-wire HART with LCD display
TLEH
2-wire Ex i HART with LCD display
T32
2-wire Ex i HART programmable
T53P
Ex i Profibus PA programmable
T53F
Foundation Fieldbus programmable
Code 2
Guide tube material and Contact separation
The following number determines the contact separation of the measuring chain in mm
V
=
Stainless steel
HB
=
Hastelloy B
HC
=
Hastelloy C
T
=
Titanium
Code 5
Code 6
EX
MU
Code 6:
MU = Overall resistance of measuring chain
approx. 1000 Ohm
(Only specification if option is available)
EX Control circuit Ex ia IIC or Ex ib IIC
= Overall length/ measuring range / tube 12 x 1
= Overall length/ measuring range / tube 14 x 1
= Overall length/ measuring range / tube 16 x 1
= Overall length/ measuring range / Square 25 x 15 x 1,5
K18 = 18mm resolution
K15 = 15mm resolution
K10 = 10mm resolution
K5
= 5mm resolution
Rev 8
07/05/2014

Werbung

Inhaltsverzeichnis
loading