Herunterladen Inhalt Inhalt Diese Seite drucken

System Control; Float Valve; Way Switch-Over Valve; Pressure And Flow Rate Sensor „Brio - Garantia 202040 Einbauanleitung

Trinkwasser-nachspeisemodul
Vorschau ausblenden Andere Handbücher für 202040:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3.1

System control

The control is determined by a float switch installed in the tank.
3.2

Float valve

Operating temperature
Operating pressure
Flow rate max.
Connections
3.3

3 way switch-over valve

Voltage / Frequency
Output
Flow rate max.
Opening time
Close time
Pressure max.
Allowable pressure differential 0.7 bar
Pressure and flow rate sensor „Brio"
3.4
Voltage / Frequency
Nominal current
Start-up pressure
(factory setting)
Start-up pressure adjustable
between
Operating pressure max.
Volume flow rate max.
Protection classification
Restarting after dry running the pump is possible by means of the "RESET" button.
If there is a water pressure hammering in the system due to the rapid closing of valves (e.g. solenoid valve
in the high pressure cleaner) then please contact the GRAF Company.
3.5

Pump

Drive unit
3.5.1 Mains water back-up supply
Power consumption
Pump head height max.
Pressure max.
Pump discharge rate max.
Suction height max.
Suction length max.
Concerning suction height as a function of the suction length see also diagram 1.
info@garantia.eu
www.garantia.eu
3.
Technical data
30°C max.
0.3 – 4.5 bar (if there is too strong water pressure a pressure reducer must
be installed!)
3
1.7 m
/h
3
" OUTSIDE THREAD
/
4
230 V / 50Hz
6 W (bei Ventilbewegung)
3
16 m
/h
ca. 10 sek
ca. 5 sek
10 bar
230 V / 50/ 60 Hz
12 A
1,2 bar
1-3,5 bar
10 bar
80 l/min
IP 65
Single phase AC motor 220 – 240 V / 50 Hz with integrated overload pro-
tection IP 44, isola-tion class F.
660 W
35 m
3.5 bar
3600 l/h (see also diagram 2)
6 m
15 m
17 / 27

Werbung

Inhaltsverzeichnis
loading