2.4 Connecting the floating switch and the domestic waterworks

2.4.1
Connecting the valve
Plug the earthing type plug into the adaptor plug of the floating switch. The 20 m long floating switch with
counterweight must be routed to the cistern in an empty pipe. The line must be fastened such that when
hanging at full stretch the float can float freely approx. 5 cm from the bottom of the cistern and does not
come into contact with other lines (suction line, calmed inlet, etc.). The adaptor plug should be positioned
within range of the valve connector – if necessary use an extension cable.
2.4.2
Domestic waterworks
The pressure and flow monitor is correctly connected to the power supply for the pump body at the factory.
Plug the earthing type plug for the flow monitor into the wall socket.