Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use; Maintenance And Cleaning - Oase AquaOxy 240 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für AquaOxy 240:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

- EN -

Intended use

AquaOxy 240, referred to as "unit", may only be used as specified in the following:
• For aeration and supplying oxygen to garden ponds.
• For use in water fountain systems and ponds.
• Operate in accordance with instructions.
During the winter months, the unit can be used to keep the surface of the pond free of ice and prevent the pond from
freezing up. Prerequisite for this is that the temperature does not go below the permissible minimum outside tempera-
ture for the unit.
Installation and connection
Set-up the unit
 B, C
– Install the unit flood protected in a horizontal position.
Ensure that the unit is installed with a safety distance of at least 2 m from the water.
• Install the unit above the level of the water, otherwise it will be damaged by water flowing back.
Damage resulting from incorrect installation is not basis for a claim within the framework of the guarantee or warranty.
Connect the unit
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
 D
• Keep the air hose as short as possible and lay it well protected.
• Connect the aeration stone to the air hose and position the aeration stone in the pond.
• Attach the free end of the air hose to the air outlet on the unit.
Commissioning/start-up
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.

Maintenance and cleaning

W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
Cleaning the air filter
 F
• Undo the screws on the underside of the housing and remove the upper section of the housing together with the
sealing ring (E).
• Use a screwdriver to remove the filter holder (G, 4) from the upper section of the housing.
• Remove and shake out the filter fleece (G, 5).
• Push the cleaned fleece (G, 5) back into the filter holder (G, 4).
• Reassemble the unit in the reverse order.
10

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis