Close the stop valve of the water sup-
ply.
Depressurise the system, in order to do
so, set the programme button to the Po-
sition 2 - Backwash position.
Cleaning the injector sieve:
Unscrew and clean the injector sieve.
Grease the O-ring with silicone grease.
Cleaning the injector:
Unscrew the injector cap, pull the injec-
tor out using pliers and clean it.
Reinstall everything.
Open the stop valve of the water sup-
ply.
Bleeding the suction hose:
Perform initial start-up or press control
valve flap 1.
Appendix
Detail control valve
1 Air seal valve
2 Ball float
3 Suction hose (red)
4 Salt volume regulator
Pre-set, adjustment is not permitted
Control valve flaps
The control of the control valve flaps takes
place via the cams on the camshaft (not
shown) of the programming unit.
1 Saline solution (bleeding of the suction
hose)
2 Inlet
3 Outlet
4 Bypass
5 Backwash/drain
6 Rinsing/drain
Function control valve flap
1 Valve casing
2 Valve flap closed
3 Valve flap open
4 Cam (camshaft)
Description air seal valve
1 Ball float in open position
2 Ball float in closed position (air in the air
seal valve)
3 Suction hose (red)
If the salt tank is empty, the suction hose
draws air into the air seal valve. The ball
float moves down and closes the valve.
Bleeding the air seal valve: Fill the salt
tank, then perform initial start-up.
If air is caught in the air seal valve without
the salt tank being empty, the suction sys-
tem is not properly bled.
Bleeding the air seal valve: Repeat ini-
tial start-up from step 5.
4
-
EN
11