Other functions
Connecting cable device/cigarette
lighter
The supplied connecting cable has two functions:
Use the device as a data memory when
you change the battery of your vehicle.
Connect the Power Start with the connection ca-
ble to the vehicle's cigarette lighter before you
remove the battery.
Note
In some vehicles, the ignition has to be
switched on to provide a current connec-
tion with the cigarette lighter.
Charge the Power Start via the ciga-
rette lighter.
Attention !
This function is only available for WPS 12-700
and WPS 12-900!
Connect the Power Start with the cigarette lighter.
Note
This function is especially intended for
service vehicles that are in use often.
Indicator to determine the on-board
voltage (only for WPS 1224-700 and
WPS 1224-900)
Set the operating switch [3] to the "0" position.
Connect the battery terminals [9] with the plus
and negative terminal of the vehicle battery.
The vehicle battery voltage is shown on the
3
display [6].
When the displayed value is larger than 15 V, then
an on-board voltage of 24 V is present.
When the value is smaller than 15V, checking the
on-board voltage according to the manufacturer
information is required.
18

Replacing the fuse

Risk of electric shock
Switch the device off before
¾
changing a fuse.
Disconnect the device from other
¾
devices.
Switch off the device using the operating
switch [3].
Disconnect the device from all other devices.
Let the fuse cool down completely (about 5 minutes).
To open the fuse holder [2] , remove the cover.
Loosen the two nuts and the bolts that attach the
fuse on the positive cable.
Remove the old fuse and insert a fuse of the same
type (see Technical Specifications).
Attach the fuse with the two nuts and bolts.
Attach the cover again on the fuse-holder.

Maintenance / Care

WARNING !
Risk of fire or electric shock
Disconnect the device from the
¾
power supply, prior to performing
maintenance or repair work.
Charge the device permanently when not in use
The Power Start can be connected at all times to
the automatic charger with no risk of damage.
Protect the device against humidity and moisture.
Clean the device only by using a clean, dry cloth.
Store the device in an upright position in a cov-
ered, cool and dry place.
Check the unit before each use and every
30 days for damage.