3. ASSEMBLY INSTRUCTIONS

1. Calculate the pool's capacity. Add 5-6 Kg of salt per m
2. Balance the Ph between 7.2 and 7.6. In fibreglass pools, 6.8 – 7.0.
3. If the water has been newly added, use 1 Kg of CHLORINE STABILISER FOR
EVERY 25 CUBIC METRES.
4. Open the filter. Clean it and add sand, 2 or 3 centimeters above the upper
tube (if it is a diatomaceous filter, do not touch it).
5. Electrical wiring. Check the 220 V power socket, your «Natural Chlor»
chlorinator operates at 210-230 V and requires earthing. Connect the chlorinator
through the timer in order to allow the chlorinator to switch itself on and off
automatically with the water filter.
The cell should be installed at the filter outlet, after the heater (solar
heating) valves, etc... There must be enough room to allow the cell to be
dismantled for cleaning (see diagram below and graphic on page 28).