Technical data
Item
Power supply
Degree of protection IP 40
Overvoltage
category CAT III
TÜV/GS

Operation

Non-contact magnetic field detection
By means of its integrated electric circuit, the device
is able to detect magnetic fields of all sorts, e.g.
solenoid valves in heating systems, solenoid valves
in commercial vehicles, print relays on circuit boards
etc.
Check the batteries as described under Perfor-
mance check.
Check the object with the test probes [1].
The lamp illuminates if the object is magnetically
activated.
Note
To perform the check it is not necessary
to stop the machines and devices.
Performance check
Remove the test magnet from the device cover.
Touch the test magnet with the test probe [1].
3 The lamp illuminates.
If the lamp does not illuminate, replace the
batteries.
Battery exchange
Using a suitable screw driver, apply force to the
groove of the battery compartment cover [2] and
lever the battery compartment open.
Note
Pay attention that the new battery is
inserted in the correct polarity!
0715 53 150
2 x 1.5 V type AAA Micro
1000 V
IEC/EN 61010-1
(DIN VDE 0411)

Maintenance / Care

Keep the device always dry and clean.
If the device has become soiled due to daily
use, the housing can be cleaned with a damp
cloth.
Note
Never use aggressive cleaning agents
or solvents for cleaning.

Environmental protection

Do not dispose of the device with
domestic waste. Have the device
disposed of by an authorised waste
management company or your
municipal waste management
organisation. Adhere to the applica-
ble regulations. In case of doubt
contact your waste management organisation.
Recycle all packaging material in an environmen-
tally friendly manner.
Batteries:
Do not dispose of batteries with domestic waste,
do not expose to fire or water. Collect and recy-
cle batteries or dispose of with due care for the
environment.

Warranty

This Würth device is covered by warranty according
to the applicable national regulations. The warranty
period begins on the date of purchase (please retain
invoice or delivery note as proof of purchase).
Faults covered by warranty shall be eliminated by
replacement or repair. Damage caused by improper
operation is not covered by warranty.
Claims can be recognised only if the device is in a
non-disassembled state and presented to a Würth
branch office, your Würth sales representative or a
customer service office authorized by Würth.
Technical changes reserved.
We accept no liability for printing errors.