Drive controller
If the UCR520 is used as a drive controller, the drive is connected directly to
the device. External signals are converted into control commands. The coding
switch 2 must be in the lower position.
Group controller
If the UCR520 is used as a group controller, other group controllers/drive con-
trollers can be controlled. This control can relay external switching signals.
This function can be used to connect groups and carry out joint switching com-
mands. The coding switch 2 must be in the upper position.
Roller shutter or venetian blind
Encoding Switch 3 is used to select roller shutter mode (lower position) or vene-
tian blind mode (upper position). When the venetian blind mode is selected,
the venetian blind moves in nonmaintained command mode in order to allow
for the blind slats to be positioned precisely. If a control command button is
held pressed for more than 1 second, the venetian blind will move in maintained
command mode.
Functions in manual mode (on the device and via radio
control)
• UP, STOP, DOWN
• Intermediate position
• Ventilation/adjustment position
• Emergency signals
Functions in automatic mode
• External automatic drive commands
• UP, STOP, DOWN
• Intermediate position
• Ventilation/adjustment position
• Emergency signals