9. MAINTENANCE & CLEANNING
Excess glue needs to be removed according to
demands.
Make sure machine is "disconnected from power
source" and "Wait for machine to cool down" before
any maintenance.
Edging Surface (1): Remove excess glue with cloth & solvent.
Press Roller (2): When coarsely soiled remove Roller and clean
it with cloth & solvent.
Fence (3): Remove excess glue with cloth & solvent.
Removable Lid (4): Lid is located on bottom of Housing. Excess
glue accumulated can be removed easily.
Pressing Plate (5): Remove Cover (6) and clean pressing plate
with cloth & solvent when needed.
Glue reservoir: Excess glue around Heating Unit does not need
to be cleaned. It will be re-melted on next operation.
We recommend spraying Virutex "CANTSPRAY" over tape guides and
gluing rollers before starting to edge. It reduces considerably the
adhesion of the glue on working elements and is easily cleaning.
10. NOISE LEVEL AND VIBRATIONS
These levels have been measured according to the European
Standard EN50144.
Noise level at work area can exceed 85 dB (A). In that case operators
should protect themselves against damage to hearing.
11. WARRANTY
All VIRUTEX machines are guaranteed for 12 months from the date
of purchase, excluding any damage which is a result of incorrect
use or of natural and tear on the machine. All repairs should be
carried out by the official VIRUTEX technical assistance service.
VIRUTEX reserves the right to modify its products without prior
notice.