General Description

Scope of Delivery

-
Home water dispenser
-
Automatic switch
-
Connecting piece
-
Carrying handle
-
Srews
-
Instruction Manual
The diagram of the most impor-
tant functional elements can be
found on the foldout side.

Overview

1
Water outlet, automatic switch
A
2
Protective cap for male thread
3
Protective cap for female thread
4
Water inlet, home water dispens-
er
5
Protective cap for female thread
6
Water outlet, home water dis-
penser
7
On/Off switch
8
Power cable
9
Carrying handle
10
Srews
11
Filler screw
12
Connecting piece
13
Draining screw
14
Protective cap for male thread
15
Water inlet, automatic switch
16
"Alarm" indicator
17
Restart switch
18
"Pump On" indicator
19
"Power On" indicator
20
Automatic switch

Functional description

The home water dispenser pumps water
automatically. The pump will turn on and
convey water at turn-on pressure. The turn-
on point is set in the factory and cannot be
adjusted by the user.
Read the sections below to learn more
about each operating element's function.
Technical Data
Home.water.dispenser.. F HA.1100.B2
Mains connection ............230 V~, 50 Hz
Power consumption ............... 1100 Watt
Suction lift ...................................... 7 m
Max. discharge rate ................4.600 l/h
Max. discharge head .................... 45 m
Max. water temperature ................ 35 °C
Hose connection ............................... 1"
Turn-on pressure ..........0,2 MPa (2,0 bar)
Turn-off pressure ........0,45 MPa (4,5 bar)
Maximum pressure ..........1 MPa (10 bar)
Safety class ......................................... I
Degree of protection ........................IPX4
Noise pressure
level (L
) ........74 dB(A); K
pA
Noise performance level
(measured) / (L
)
WA
............... 88,2 dB(A ); K
Noise performance level
(guaranteed) ............................. 91 dB(A)
The stated values relate to the use of the
automatic domestic water pump without
automatic switch DSK-19. The values may
differ slightly as a result of use with the au-
tomatic switch.
GB
= 3,0 dB(A)
pA
= 2,89 dB(A)
WA
25