2. INSTALLATION

Instructions which must be followed by the drive and home automation professional installing the Irismo
mini motor.
Never drop, knock, drill or submerge the drive.
Install a separate control point for each drive.
2.1. INSTALLATION
2.1.1. Installation of the rail (Fig A)
1) Mark the position of the brackets.
2) Drill the ceiling or the wall at the right places.
3) Attach the brackets.
4) Attach the rail on the brackets.

2.2. WIRING

(Fig C)
Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
Attach cables to prevent any contact with moving parts.
Leave the drive power supply cable accessible: it must be possible to replace it easily.
Connect the power supply jack into the motor (Use only the Somfy power supply with this motor).
-
Plug the connector of the power lead into the other end of the power supply and plug the pin plug into the electricity supply
-
wall socket.
DCT wiring
(Fig D)
1
CCW (Open) NO Dry contact
2
3
Compatible controls - Wiring of control
1) Setting tool
2) Centralis IB
3) 2 NO (Normally Open) Dry contact switch

2.3. COMMISSIONING

DCT Setting tool
2.3.1. Pre-programming the RTS control point (only for RTS version) (Fig F)
1) Connect the power supply DC plug to the motor, and connect the power supply socket to the main socket.
2) Press the Open and Close buttons on the RTS control point at the same time: The motorised product moves up and down, and
the RTS control point is pre-programmed in the motor.
2.3.2. Setting the end limits
At the first command Open or Close, the motorised product make a first run to record the hard stop position.
4
IR OUT
Ground Common
my/Stop
Caution!
2.1.2. Installation of the motor (Fig B)
1) Unlock the motor
2) Insert the motor shaft into the drive pulley hole.
3) Lock the motor.
4
+5V
5
Stop - NO Dry contact
6
CW (Close) NO Dry contact
(Fig E)
RTS control point
Open
Close