Installation

7. Installation
!
On installation, the minimum distance
be twe e n the hob and the hood must be
e xactly complie d with (se e chapte r 7.1
"Installation data") and follow the num-
be ring of the ste ps and the additional
instructions. Exe cution with air e xhaus-
ted outdoors (A- see also the installation
data). The vapours are e xtracte d via an
air exhaust hose fixed to the connector
ring.
The diame te r of the e xhaust air hose
must conform to that of the conne ctor
ring. If a smoke non-return valve is used
or is planned, check whether it can open
and close freely after the installation of
the exhaust air hose. The extractor hood
can be e quippe d with one (top) or two
(top and back) extractor openings.
The hood is normally initially fitted out
for use of the top e xtractor ope ning, as
an extractor hood.
Openings not required are fitted with a
plastic cove r. This plastic cove r can be
e asily re move d by turning counte rclock-
wise and optionally fitted to another ope-
ning which is not required.

7.1 Installation data /

dimensions
Minimum distance from the lowe r e dge of
the hood body:
to ceramic and cast cooking hobs 65 cm.
to gas hob 70 cm.
to hobs with coal/oil/wood firing 85 cm.