OPERATING CONDITIONS & REQUIREMENTS
OPERATING PRESSURE MIN-MAX: 2,5-8,0 bar / 36-116 psi
 low operating pressure may lead to insufficient backwash of the
filter media, resulting in an increase in pressure drop and/or a
reduction of the filtration capacity during the service cycle.
 if installed on a well, verify that the well pump is powerful
enough to provide sufficient flow rate for the backwash cycle.
 check water pressure regularly.
 take into account that night time water pressure may be
considerably higher than day time water pressure.
 install a pressure reducer ahead of the appliance if necessary.
OPERATING TEMPERATURE MIN-MAX: 4-48 °C / 39-120 °F
 do not install the appliance in an environment where high
ambient temperatures (e.g. unvented boiler house) or freezing
temperatures can occur.
 the appliance cannot be exposed to outdoor elements, such as
direct sunlight or atmospheric precipitation.
 do not install the appliance too close to a water heater; keep at
least 3 m (10 ft) of piping between the outlet of the appliance
and the inlet of the water heater; water heaters can sometimes
transmit heat back down the cold pipe into the appliance;
always install a check valve at the outlet of the appliance.
ELECTRICAL CONNECTION:
 this appliance only works on 24 VAC; always use it in
combination with the supplied transformer.
 in case of damage to the power supply cable of the transformer,
immediately disconnect the transformer from the power outlet
and replace the transformer.
 make sure to plug the transformer into a power outlet, which is
installed in a dry location, with the proper rating and over-
current protection.