ADJUSTING THE COMMANDS
ELECTRIC DRIVE TYPE 2
LIMIT STOP ADJUSTMENT SLOPE 95 MOTOR
When there is an electrical current, proceed with maximum
caution in accordance with the safety regulations in force.
When the structure has been assembled, and before fixing the
awning canvas to the sliders, check that the transmission
system is properly connected: shafts, tubes, side shafts and
motor heads.
- Check that the motor is correctly connected to the exchange
and that the exchange is correctly connected to the mains.
- Press the START button (1) on the exchange and wait for the
red LED to come on (2), then release the button.
The sliders will begin to move out; when they reach the end
they stop for 1 second and then automatically begin to go
back up.
- Press the STOP button (3) at the point at which you wish the
awning canvas to stop retracting.
It is then possible to use the remote control supplied.
Then proceed with assembly of the awning. The tension of the
canvas when opening is managed by the exchange, whilst the
point at which the stacked awning stops is the point
memorised with the STOP button.
If the motor stops (because of overheating), the red LED (2)
flashes: after approximately 5 minutes the light goes off and
the motor can be used again.
N.B. After attaching the awning canvas to the runners, repeat the
operation.
Tuning a new remote control
Press the MEMO button (4), the LED (5) flashes twice, keep the
MEMO button (4) pushed down and press the remote control
button at the same time, the LED (5) flashes twice indicating
34 of 119
that the remote control has been recognised.
Cancelling remote control memory:
You can cancel all the remote control codes by pressing the
CANC button (6) and waiting for the LED (5) to stay
permanently red.
~
M1 1
M1 = SLOPE 95
230V~ / 50Hz
In = 0,97 A
Pn = 218 W
IP = 54

Data sheet 2

Push-button panel maintained,
supplied and installed by an
electrician. Positioned within the
awning's operating field
CORRADI SPA - USER MANUAL - IMPACT
5
6
4
Fu 250V/200mA
6P+T
2P+T
Insul. Transf.
Ensure the
Exchange type
MONO 00749
common wire is in
central position
RETRACT
WORK MUST BE CARRIED OUT BY INSTALLER
MONO 00749 Exchange
With automatic opening limit switch
including a remote control.
Retract button
Extend button
3
2
1
)
(
Plug supplied
1 = Brown
to be wired
2 = Blue
and insert
= EARTH
WIRE TYPE
FG70R 3X1,5 mmq
NETWORK B.T.
EARTH
Low
voltage
5V
2x6 A
Id=0,03A
Id
4,5KA
EXTEND
7 - 04.2011