Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Functional test
To perform a function test, it is necessary to set a short switch-on time (turning the dial „TIME"
to the setting „10S"). In addition, the dial for brightness („LUX") must be turned completely to
the right (in the direction of the sun symbol).
The desired sensitivity is to be set with the knob „SENS". For the first test, set the knob in the
middle position.
Now cross the detection range. The motion detector activates the connected device when it
detects motion within the detection range. In addition, a green LED lights up on the motion
detector.
Set the dial accordingly after performing the function test. Then check whether the motion
sensor responds the way you want under real-life conditions and adjust the setting of the dial
step-by-step.

Troubleshooting

The connected device is not switched on
• Check the settings for the dial „LUX" used for the brightness control. Turning it too far to the
left (anticlockwise) will cause the motion detector to activate only when it is dark.
• Check whether it is powered, and whether the device, (for example a lamp. a bulb) function-
ing.
• Increase the sensitivity (turning the dial „SENS" towards „+").
• Rapid movements within the monitoring area are filtered out by the electronic system in order
to prevent switching errors.
The connected device is switched on permanently
• There are constant movements within the monitoring area; this can also be a motion in an
adjoining room detected by the high frequency technology used. Reduce the sensitivity (turn-
ing the dial „SENS" towards „-").
Please note: If the motion detector is activated by a movement and a new movement is
detected during the on-time, the duty cycle starts again!
• Set a very short switch-on time for testing, in order to narrow down the causes.
The setting of the dial control "LUX" is not working properly
• Always make sure that the brightness sensor is not covered.
• Ambient light prevents functioning at night. Turn the dial a bit more towards the sun symbol
(thus the motion detector will already work in brighter surroundings).
Care and cleaning
• Disconnect the product from the mains supply before each cleaning procedure.
• Never use abrasive cleaning agents, rubbing alcohol or other chemical solutions, since these
could damage the casing or even impair operation.
• Use a dry, lint-free cloth to clean the product.
Disposal
Electronic devices are recyclable material and do not belong in the household
waste. Dispose of an unserviceable product in accordance with the relevant statu-
tory regulations.
Declaration of conformity (DOC)
We, Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this
product conforms to the 2014/53/EU directive.
The full text of the EU conformity declaration is available via the following Internet
address:
www.conrad.com/downloads
Select language by clicking a flag symbol and enter the order number of the product
in the search field; then you will be able to download the EU declaration of conform-
ity in PDF format.
Technical data
Operating voltage ................................. 220 - 240 V/AC, 50/60 Hz
Internal power consumption ................. approx. 0.9 W
HF system ............................................ 5.8 GHz, CW radar, ISM band
Transmitting power ............................... < 0.2 mW
Switching power .................................. max. 500 W (resistive load)
..............................................................
Devices with mainly resistive load are, e.g., light bulbs, heaters, etc.
Devices with inductive load are, for example, engines, control gears (e.g., for LEDs),
conventional transformers, energy saving bulbs, etc.
Switch type ........................................... relay, single-pole
Permissible line cross section
for connection terminals ...................... 0.75 - 1.5 mm²
Detection angle ..................................... 360° horizontal , 180° vertical
Range ................................................... adjustable, approx. 1 - 15 m
Recommended mounting height .......... wall mount: 2 - 6 m
..............................................................
Speed for motion detection ................... 0.6 - 1.5 m/s
Duty cycle ............................................. adjustable 10 s (±3 s) to 12 min (±1 min)
Ambient brightness ............................... adjustable, 3 to 2000 lux
Installation site ...................................... only in dry enclosed rooms
Ambient conditions ............................... temperature -20 °C to +40 °C, air humidity 0% to 93%
Dimensions ........................................... 61.5 x 37 x 25 mm (L x W x H)
Weight .................................................. approx. 50 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
© Copyright 2017 by Conrad Electronic SE.
max. 150 W (inductive load)
wall mounting: 1.5 - 3.5 m
relative, non-condensing
1530623_V1_0517_02_VTP_m_en

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis