Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications; Troubleshooting - STEINEL CAM light Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
12� Technical specifications
Dimensions ( H × W × D )
305 × 78 × 131 mm
Power supply
220 - 240 V, 50 / 60 Hz
Power consumption
14.3 W
Luminous flux
781 lm
Efficiency
54 lm/W
Colour temperature
3000 K ( warm white )
Colour rendering index
Ra ≥ 80
Life expectancy
50,000 hours ( L70B10 to LM80 )
Sensor technology
Passive infrared
Communication
Wi-Fi 2400-2483.5 MHz
Transmitter power
< 100 mW
Angle of coverage
180° with 45° angle of aperture
Mounting height
1.8 - 2 m
Detection reach
10 m tangential
Light-level setting
10 - 10,000 lux
Night light
0 - 40%
Time setting
1 min, 3 min, 10 min, 15 min
Camera
Resolution 1280 × 720 pixels
Dazzle guard
Angle of aperture 110° H / 90° V
Vertical angle 20° to 30°, horizontal angle 45° to
each side
Supports memory cards up to 32 GB ( an 8 GB
memory card is included with the camera light )
Temperature range
-10°C to +40°C
IP rating
IP44
Protection class
I
18
13� Troubleshooting
Malfunction
Cause
Camera light without
■ Fuse has tripped, not
power
switched ON, break in wiring
■ Short circuit in mains power
supply lead
■ Mains switch OFF
Camera light not
■ Incorrect twilight setting
switching ON
selected
■ Mains switch OFF
■ Fuse has tripped
Camera light not
■ Continued movement within
switching OFF
the detection zone
Camera light
■ Camera light not mounted
switches ON without
for detecting movement
obvious movement
reliably
■ Movement occurred, but not
identified by the observer
( movement behind wall,
movement of a small object
in immediate lamp vicinity
etc. )
Camera light not
■ Rapid movements are
switching ON
suppressed to minimise
despite movement
malfunctioning or detection
zone set too small
■ Incorrect twilight setting
selected
No access to
■ Wi-Fi router is too far from
camera light via app
the camera light or building
elements, such as walls, are
obstructing transmission
Smartphone/tablet
■ A terminal device is already
cannot be connect-
connected
ed to camera light
No live image
■ Temperature too high
transmission
Remedy
■ Activate, change fuse, turn
ON power switch, check
wiring with voltage tester
■ Check connections
■ Switch on mains switch
■ Readjust
■ Switch ON
■ Activate, change fuse, check
connection if necessary
■ Check detection zone
■ Securely mount enclosure
■ Check detection zone
■ Check detection zone
■ Readjust
■ Use repeater
■ Press reset button or scan
QR code from connected
terminal device
■ If necessary, deactivate
manual override and let cool
down
19

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis