UK | 10 Humidity

10 Humidity

Set the desired humidity range to suit your
physical comfort in this menu.
The humidity value currently measured ap-
pears in the Overview or Humidity menu.
Dehumidification of the living areas with in-
tensive ventilation generally takes place when
the Rel. humidity max value limit is exceeded.
With linear sensor control
Between the min and max value limit, the air
volume (volumetric flow) needed for dehumid-
ification changes in a continuously variable
fashion between reduced ventilation and
intensive ventilation.
Reduced ventilation (level I) activates when
the value falls below the set Rel. humidity min
value limit.
With stepped sensor control
The unit increases to intensive ventilation when
the Humidity max value limit is exceeded.
In the case of unsuitable outside air
i
that is too humid (summer storms),
the intelligent control deactivates the
dehumidification function.
For adjusting the room humidity values
in the event of sensor measurement devia-
tions Chapter 17.6.
54
Rel. humidity min value limit
Lower value limit for needs-based humidity
control in Auto Sensor operating mode
– with linear setting.
Ventilation unit switches to ventilation level I
(reduced ventilation) when value falls below
Humidity min value limit.
This function is deactivated if humidity control
is set to stepped.
Rel. humidity max value limit
The Humidity max value limit is always used
as a switching point for dehumidification,
regardless of the set operating mode (excess
humidity protection).
Ventilation unit switches to ventilation level
III (intensive ventilation) when value exceeds
Humidity max value limit.
If the value falls below the value limit with
needs-based humidity control (Auto Sensor
operating mode, linear setting), humidity is
controlled in a continuously variable fashion
according to automatic humidity function.
With the stepped setting, the value limit
serves as a switching point for switching the
humidity control on/off.