6. Information on commissioning, use and maintenance
The couplers for connection or extension cables must be designed to be at least splashproof.
●
Repairs may only be carried out by authorized aftersales offices or by staff familiar with at the relevant safety
●
regulations.
Please note: These appliances are not suitable for vacuuming health-damaging dusts or easily flammable, combustible,
●
toxic, caustic or irritant substances..
They are only designed for use on level surfaces with a maximum incline of up to 2% and approved not for use on
●
public roads or paths.
Finishing the clean job / Maintenance
7.
Switch-off the vacuum cleaner.
●
Un-plug the unit from the electrical supply.
●
Rinse the dust and water tank with clean water.
●
Clean the entire unit with a damp cloth.
●
The unit may never be cleaned with means of a high pressure cleaner.
●
Only use original spare parts and accessories when repairing the unit.
●
Repairs may only be made by authorised specialists who have full training on the maintenance of the vacuum cleaner.
●
Careful maintenance will prolong the lifetime of the wet and dry vacuum cleaner.
8. Interference / Troubleshooting
Before working on the machine disconnect mains cable!
Only do repairs and service that are mentioned in these operating instructions.
Leave service and repairs, especially repairs on electrical componants, the after sales service of an authorised
service agent.
The following advise will help you detect faults and help you resolve them:
Disturbance
Machine does not work
Insufficient Vacuuming performance
If the vacuum cleaner does not work after checking above faults, please contact authorised service agent!
Technical data
Voltage
Vacuum motor
Suction (vacuum)
Effective volume of water
Cable length
Working width
Weight
Dimensions L / W / H
Storage
If the machine is not used store it dry and keep the room temperature always above 0° degree.
SW 60 - Englisch
Reason
☞ Connections not plugged-in
☞ Suction hose (a), tubes (b)
☞ Tool (c,d,e,f oder g) clogged or
☞ Dustbag (h) full
☞ Motor cover (4) not placed properly
Removal
Check connections.
●
Check hose, tubes,
●
bag and tools and
●
remove any blockages.
●
Fit motor cover (4) properly.
●
SW 60
2 Engines
230 V
013.000SEV
2 x 950W
190 mbar
56 liter
10 m
42 cm
21,3 kg
61/52/92cm
3 Engines
013.001SEV
013.001VDE
2 x 950W
1 x 1000W
205 mbar
26 kg
9