View motherboard

fuse mains
mains connector
spare
fuses
T0,2A

Technical Data

Type
Nominal voltage
Rated power
Stand-by operating
Class of rating
Protection class
Ingress protection
Temperature range
Output voltage
Output current
Housing
Colour
Dimensions
8/12
GVL 8301-K
230 V protection cap
GVL 8301-K
230 V AC, 50 Hz
30 VA
4,3 W
short-time duty, 20%
II
IP 54
-5...+60°C
24 V DC, unstabilized
max. 1 A
plastic
light grey (~RAL 7035)
139 x 119 x 70 mm
connector for
central control
CLOSE diode
Safety function!
The CLOSE diode, marked above, must be cut out
with side cutting pliers, if the window, which is to
open, is within arm's reach (fitting heights of the
window less than 2,5 m). Through this, a „key
operation function" will be achieved with closing of
the window. The window wing will be closing only
as long as the vent button is operated.
In this case, automatic control is not permissible,
e.g. by room temperature control or wind/rain
detector.
Observe the safety notes which are
included to the drive!
English
drive connector
CLOSE
Diode
(s.b.)
OPEN
Diode
99.821.72 1.4/02/16