Wiring plan (Paragon)
to further ones
Line lenghts and cross sections
total current
type
0.5 A
240
2x 1,5 mm²
400
2x 2,5 mm²
640
2x 4 mm²
cable lenght (m) x total current
Cross section (mm²) =

230 V AC supply

L
N
PE
99.821.72 1.4/02/16
window drive
see line lenghts and cross sections
4x 0,8 Ø
vent button
ca. 1,2 m above
upper edge
firm flooring
1 A
120
m
200
m
320
m
80
230 V AC, 50 Hz
4x 0,8 Ø
rain sensor
Output voltage 24 V DC!
Do not run cables together with power lines!
In case of a cable with ground wire
(e.g. green / yellow) this must not be used!
Covering
Place enclosed protection cap
over supply terminal after mains
cable has been connected.
English
control panel
230 V AC, 50 Hz
2x 0,8 Ø
external
control
4x 0,8 Ø
room temperature
control
GVL 8301-K