of maintenance. Continuous satisfactory operation
depends upon proper tool care and regular cleaning.
WARNING: To reduce the risk of
injury, lock off trigger, disconnect air
line from tool and remove fasteners
from magazine before making
adjustments or personal injury may
result.
Perform the following maintenance
operations every day:
Lubrication
Lubricate tool with 10-15 drops of D
pneumatic tool oil
Insert drops into the air fitting on the end cap of the
tool.
Drain all condensation from the air
compressor tanks and hoses
• Open petcocks or other drain valves on the
compressor tanks.
• Allow any accumulated water to drain from
hoses.
Cleaning
CLEAN MAGAZINE, PUSHER, AND CONTACT TRIP
MECHANISM
WARNING: Blow dirt and dust out of
the main housing with dry air as often as
dirt is seen collecting in and around the
air vents. Wear proper eye protection
when performing this procedure.
WARNING: When cleaning, use
only mild soap and a damp cloth on
plastic parts. Many household cleaners
contain chemicals which could seriously
damage plastic. Also, do not use
gasoline, turpentine, lacquer or paint
thinner, dry cleaning fluids or similar
products which may seriously damage
plastic parts. NEVER let any liquid get
inside the tool; NEVER immerse any
part of the tool into a liquid.
32
Ensure that all fasteners on the
tool are tight and undamaged
Tighten loose fasteners using the appropriate tool.
TROUBLESHOOTING
If your tool seems not to operate properly, follow
the instructions below. If this does not solve the
problem, please contact your repair agent.
Tool does not work
• Check the air supply.
• If the temperature is low, warm the tool up.
Tool has insufficient power
WALT
E
• Check the air supply.
• Check if the air exhaust is clear.
• Lubricate the tool.
Tool cap leaks air
• Tighten the cap screws.
Tool skips nails
• Check the air supply.
• Lubricate the tool.
• Clean the magazine and nosepiece.
• Check that the magazine latch is holding the
magazine firmly.
Fasteners jam in tool
• Make sure only to use fasteners of the type
specified.
• Check that the magazine latch is holding the
magazine firmly.
• Tighten the nosepiece screws.
Optional Accessories
WARNING: Since accessories, other
than those offered by D
not been tested with this product, use
of such accessories with this tool could
be hazardous. To reduce the risk of
injury, only D
accessories should be used with this
product.
Consult your dealer for further information on the
appropriate accessories.
WALT, have