4/ Setting Menu:

On this menu you have all adjustable parameters of your system.
Several parameters are not available with all systems.
4.1/ Maxtemp tank1:
- Maximum value of desired water temperature on the tank1 during normal
operation. (Adjustable 15 to 95°C with factory value 65°C)
4.2/ dTMax tank1:
- Difference between collector temperature (T1) and Tank1 temperature (T3)
to start the main pump1. (Adjustable 3 to 40°C with factory value 7°C)
4.3/ dTMin tank1:
- Difference between collector temperature (T1) and Tank1 temperature (T3)
to stop the main pump1.
(Adjustable 2 to (dTMax tank1 -2°C) with factory value 3°C)
dT = T1 – T3
Maxtemp
Tank1
100%
P1
0%
4.4/ Maxtemp tank2: (Available only with system with two tanks (2 and 3))
- Maximum value of desired water temperature on the tank2.
(Adjustable 15 to 95°C with factory value 65°C)
4.5/ dTMax tank2: (Available only with system with two tanks (2 and 3))
- Difference between collector temperature (T1) and Tank2 temperature (T5)
to start the main pump1 with system2 or pump2 with system3.
(Adjustable 3 to 40°C with factory value 7°C)
4.6/ dTMin tank2: (Available only with system with two tanks (2 and 3))
- Difference between collector temperature (T1) and Tank2 temperature (T3)
to stop the main pump1 with system2 or pump2 with system3.
(Adjustable 2 to (dTMax tank2 -2°C) with factory value 3°C)
Remarks:
With a system with two tanks the working of the second tank is the same
that to explain (graph) above except the used sensors for the measuring.
The tank loadings priority is chosen on the "Service" menu (part 5.12 ).
dTMax
dTMax
Pump speed regulation
dTMin
dTMax
9
GB
Collector
T1 (°C)
Tank1
T3 (°C)