Replacing the Fuse

If you have to replace the fuse, ensure that you only use fuses of the specified type and rated current (see
"Specifications").
Never repair fuses or bridge the fuse holders.
Switch the device off at the CIRCUIT BREAKER (put switch into OFF position).
Pull the mains plug from the mains socked and disconnect all loads connected from the output sockets.
Open the fuse holder for the defective fuse with a suitable screwdriver.
Remove the defective fuse and replace it with a fuse of the type indicated.
Now screw the fuse holder with the replaced fuse back into the socket.
After that, reconnect the loads to the device, the device to the mains and put it into operation again.

Disposal

At the end of its service life, dispose of the product according to the relevant statutory regulations.

Technical Data

Operating voltage .............................................................. 230V AC/50 Hz
Total load capacity ............................................................. max. 16A/3680W
Load capacity per channel ................................................ max. 5A/1150W
Fuses .................................................................................. F6.3A/250V (5x20mm)
DMX protocol ..................................................................... DMX512
DMX channels .................................................................... 1 or 4 (switchable)
Analogue control ................................................................ 0-10V=
Dimensions ........................................................................ 319 x 110 x 175mm
Weight ................................................................................ 3kg