Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Cleaning - Oase IceFree 4 Seasons Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- EN -
Fitting the pump
N O T E
In warm temperatures, the pump must be higher in the water than in cold temperatures. More dirt particles are
generated in warm temperatures, particularly on the bottom of the pond. These may damage the pump or im-
pact its transport rate.
• Only use one hose.
• Shorten the hose if necessary.
• Use a filter bag.
 E
• See winter mode. (→ Fitting the pump)
• Enclose the pump in the filter bag and close the filter bag tightly.
– This protects the pump from fine dirt particles.
Commissioning/start-up
N O T E
Prevent the pump from running dry. Otherwise the pump will be destroyed.
• Only operate the pump when it is immersed.
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.
Remedy of faults
S
Malfunction
The unit does not deliver water

Maintenance and cleaning

For cleaning and maintenance, take the unit out of the water and dismantle it. If necessary, the impeller unit can also
be replaced this way.
W A R N I N G
Electrical current may cause death or severe injuries.
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Prior to reaching into the water, disconnect units and installations from the mains.
• Disconnect the power plug before carrying out any work on the unit.
• Secure the unit to prevent unintentional switching on.
14
Cause
No mains voltage
Hose not straight, twisted or soiled
Pump housing, filter bag and/or nozzle soiled
Volcano nozzle is completely screwed into the
nozzle pipe
Remedy
Check the mains voltage.
Check/clean hose
Clean
Unscrew nozzle slightly